Passer au contenu principal
    Tous les systèmes
    Système à Ultrasons

    Voluson S8t

    GE

    The GE Voluson S8t (BT22) is a premium women's health ultrasound system designed for obstetrics, gynecology, and reproductive medicine. Featuring an innovative 10.1" touch panel interface, CrossXBeam CRI™ compound resolution imaging, advanced Speckle Reduction Imaging (SRI II), and Coded Harmonic Imaging with Pulse Inversion Technology. Supports 3D/4D real-time imaging with HDlive rendering, SonoAVC follicle and antral counting, STIC fetal cardiac imaging, SonoVCADheart, and RadiantFlow visualization. Compatible with a wide range of RS-series transducers including convex, linear, phased array, endocavity, and 3D/4D volume probes. Features B-Flow hemodynamic imaging, elastography, coded contrast imaging, and comprehensive biometry tools including SonoBiometry and SonoNT.

    12 Sondes Compatibles

    Sondes compatibles pour GE Voluson S8t

    Standard

    Sondes Standard (10)

    GE 12L-RS ultrasound transducer

    12L-RS

    GE · Standard

    4–12 MHz

    Linear, high-frequency superficial

    Réparer
    GE 12S-RS ultrasound transducer

    12S-RS

    GE · Standard

    4–12 MHz

    Linear, high-frequency (no biopsy guide)

    Réparer
    GE 3Sc-RS ultrasound transducer

    3Sc-RS

    GE · Standard

    1–4 MHz

    Phased array, cardiac/abdominal

    Réparer
    GE 4C-RS ultrasound transducer

    4C-RS

    GE · Standard

    2–5 MHz

    Convex, general purpose

    Réparer
    GE 8C-RS ultrasound transducer

    8C-RS

    GE · Standard

    2–13.1 MHz

    Micro-convex, pediatric/neonatal (no biopsy guide)

    Réparer
    GE 9L-RS ultrasound transducer

    9L-RS

    GE · Standard

    3–9 MHz

    Linear, general/vascular

    Réparer
    GE C1-5-RS ultrasound transducer

    C1-5-RS

    GE · Standard

    1–5 MHz

    Convex, abdomen/obstetrics

    Réparer
    GE IC9-RS ultrasound transducer

    IC9-RS

    GE · Standard

    4–9 MHz

    Endocavity, gynecology

    Réparer
    GE IC9B-RS ultrasound transducer

    IC9B-RS

    GE · Standard

    4–9 MHz

    Endocavity biplane, gynecology

    Réparer
    GE ML6-15-RS ultrasound transducer

    ML6-15-RS

    GE · Standard

    6–15 MHz

    Micro-linear, musculoskeletal/superficial

    Réparer
    3D/4D

    Sondes 3D/4D (2)

    GE RAB6-RS ultrasound transducer

    RAB6-RS

    GE · 3D/4D

    2–6 MHz

    3D/4D volume, abdomen/obstetrics (requires 3D/4D Activation)

    Réparer
    GE RIC5-9A-RS ultrasound transducer

    RIC5-9A-RS

    GE · 3D/4D

    4–9 MHz

    3D/4D volume, endocavity/gynecology (requires 3D/4D Activation)

    Réparer

    Le contenu fourni sur ce site web est destiné à des fins d'information générale uniquement et est fourni sans aucune garantie quant à son exactitude, son exhaustivité ou son actualité. Veuillez noter que les fonctionnalités et la disponibilité peuvent varier selon l'environnement du système et le type de sonde, et peuvent ne pas être entièrement disponibles dans toutes les configurations.

    Besoin d'un service pour votre Voluson S8t ?

    Nous proposons réparation, prêt et sondes reconditionnées pour tous les transducteurs compatibles GE Voluson S8t.