Saltar al contenido principal
    Todos los sistemas
    Sistema de Ultrasonido

    Voluson S8t

    GE

    The GE Voluson S8t (BT22) is a premium women's health ultrasound system designed for obstetrics, gynecology, and reproductive medicine. Featuring an innovative 10.1" touch panel interface, CrossXBeam CRI™ compound resolution imaging, advanced Speckle Reduction Imaging (SRI II), and Coded Harmonic Imaging with Pulse Inversion Technology. Supports 3D/4D real-time imaging with HDlive rendering, SonoAVC follicle and antral counting, STIC fetal cardiac imaging, SonoVCADheart, and RadiantFlow visualization. Compatible with a wide range of RS-series transducers including convex, linear, phased array, endocavity, and 3D/4D volume probes. Features B-Flow hemodynamic imaging, elastography, coded contrast imaging, and comprehensive biometry tools including SonoBiometry and SonoNT.

    12 Sondas Compatibles

    Sondas compatibles para GE Voluson S8t

    Estándar

    Sondas Estándar (10)

    GE 12L-RS ultrasound transducer

    12L-RS

    GE · Estándar

    4–12 MHz

    Linear, high-frequency superficial

    Reparar
    GE 12S-RS ultrasound transducer

    12S-RS

    GE · Estándar

    4–12 MHz

    Linear, high-frequency (no biopsy guide)

    Reparar
    GE 3Sc-RS ultrasound transducer

    3Sc-RS

    GE · Estándar

    1–4 MHz

    Phased array, cardiac/abdominal

    Reparar
    GE 4C-RS ultrasound transducer

    4C-RS

    GE · Estándar

    2–5 MHz

    Convex, general purpose

    Reparar
    GE 8C-RS ultrasound transducer

    8C-RS

    GE · Estándar

    2–13.1 MHz

    Micro-convex, pediatric/neonatal (no biopsy guide)

    Reparar
    GE 9L-RS ultrasound transducer

    9L-RS

    GE · Estándar

    3–9 MHz

    Linear, general/vascular

    Reparar
    GE C1-5-RS ultrasound transducer

    C1-5-RS

    GE · Estándar

    1–5 MHz

    Convex, abdomen/obstetrics

    Reparar
    GE IC9-RS ultrasound transducer

    IC9-RS

    GE · Estándar

    4–9 MHz

    Endocavity, gynecology

    Reparar
    GE IC9B-RS ultrasound transducer

    IC9B-RS

    GE · Estándar

    4–9 MHz

    Endocavity biplane, gynecology

    Reparar
    GE ML6-15-RS ultrasound transducer

    ML6-15-RS

    GE · Estándar

    6–15 MHz

    Micro-linear, musculoskeletal/superficial

    Reparar
    3D/4D

    Sondas 3D/4D (2)

    GE RAB6-RS ultrasound transducer

    RAB6-RS

    GE · 3D/4D

    2–6 MHz

    3D/4D volume, abdomen/obstetrics (requires 3D/4D Activation)

    Reparar
    GE RIC5-9A-RS ultrasound transducer

    RIC5-9A-RS

    GE · 3D/4D

    4–9 MHz

    3D/4D volume, endocavity/gynecology (requires 3D/4D Activation)

    Reparar

    El contenido proporcionado en este sitio web tiene únicamente fines informativos generales y se ofrece sin garantía alguna de exactitud, integridad o actualidad. Tenga en cuenta que las funciones y la disponibilidad pueden variar según el entorno del sistema y el tipo de sonda, y es posible que no estén totalmente disponibles en todas las configuraciones.

    ¿Necesita servicio para su Voluson S8t?

    Ofrecemos reparación, préstamo y sondas reacondicionadas para todos los transductores compatibles con GE Voluson S8t.