Zum Hauptinhalt springen
    Alle Systeme
    Ultraschallsystem

    Voluson Expert 22

    GE

    Das Voluson Expert 22 ist eine Premium-Plattform für Frauengesundheit mit Lyric Architecture, 23,8-Zoll-HDU-Monitor, XDclear- und Volume-Matrix-Sondentechnologie, HDlive-Rendering, KI-basierten Tools (SonoLyst, fetalHS, SonoCNS) und elektronischem 4D für umfassende OB/GYN-Diagnostik.

    15 kompatible Sonden

    Kompatible Sonden für GE Voluson Expert 22

    Standard

    Standard Sonden (9)

    GE 11L-D ultrasound transducer

    11L-D

    GE · Standard

    4–10 MHz

    11L-D — Linear, 4–10 MHz, 192 el, 38 mm FOV

    Reparatur
    GE 6S-D ultrasound transducer

    6S-D

    GE · Standard

    1.5–5 MHz

    6S-D — Phased array, 2–7 MHz, 96 el

    Reparatur
    GE 9L-D ultrasound transducer

    9L-D

    GE · Standard

    3–8 MHz

    9L-D — Linear, 3–8 MHz, 192 el, 44 mm FOV

    Reparatur
    GE C1-6-D ultrasound transducer

    C1-6-D

    GE · Standard

    1–6 MHz

    C1-6-D — XDclear convex, 2–5 MHz, 192 el, 113° FOV, max 50 cm

    Reparatur
    GE C2-9-D ultrasound transducer

    C2-9-D

    GE · Standard

    2–9 MHz

    C2-9-D — XDclear convex, 3–9 MHz, 192 el, 100° FOV

    Reparatur
    GE IC5-9-D ultrasound transducer

    IC5-9-D

    GE · Standard

    4–9 MHz

    IC5-9-D — Micro convex, 4–9 MHz, 192 el, 189° FOV

    Reparatur
    GE L8-18i-D ultrasound transducer

    L8-18i-D

    GE · Standard

    4–15 MHz

    L8-18i-D — Linear, 5–14 MHz, 168 el, 25 mm FOV

    Reparatur
    GE M5Sc-D ultrasound transducer

    M5Sc-D

    GE · Standard

    1.5–4.6 MHz

    M5Sc-D — XDclear phased array, 1–4 MHz, 240 el

    Reparatur
    GE ML6-15-D ultrasound transducer

    ML6-15-D

    GE · Standard

    4–15 MHz

    ML6-15-D — Matrix linear, 4–13 MHz, 1008 el, 50 mm FOV

    Reparatur
    3D/4D

    3D/4D Sonden (6)

    GE eM6C G3 ultrasound transducer

    eM6C G3

    GE · 3D/4D

    2–6 MHz

    eM6C G3 — Electronic 2D matrix volume convex, 2–6 MHz, 8192 el

    Reparatur
    GE RAB6-D ultrasound transducer

    RAB6-D

    GE · 3D/4D

    2–8 MHz

    RAB6-D — Convex volume, 2–7 MHz, 192 el

    Reparatur
    GE RIC5-9-D ultrasound transducer

    RIC5-9-D

    GE · 3D/4D

    4–9 MHz

    RIC5-9-D — Convex volume, 4–9 MHz, 192 el, 189° FOV

    Reparatur
    GE RIC6-12-D ultrasound transducer

    RIC6-12-D

    GE · 3D/4D

    6–12 MHz

    RIC6-12-D — Convex volume, 5–13 MHz, 256 el, 190° FOV

    Reparatur
    GE RM7C-D ultrasound transducer

    RM7C-D

    GE · 3D/4D

    3.5–9 MHz

    RM7C-D — Active Matrix Array volume convex, 2–8 MHz, 576 el

    Reparatur
    GE RSP6-16-D ultrasound transducer

    RSP6-16-D

    GE · 3D/4D

    6–18 MHz

    RSP6-16-D — Volume linear, 6–18 MHz, 192 el

    Reparatur

    Die auf dieser Website bereitgestellten Inhalte dienen ausschließlich allgemeinen Informationszwecken und werden ohne Gewähr auf Richtigkeit, Vollständigkeit oder Aktualität bereitgestellt. Bitte beachten Sie, dass Funktionen und Verfügbarkeit je nach Systemumgebung und Sondentyp variieren können und möglicherweise nicht in allen Konfigurationen vollständig verfügbar sind.

    Service für Ihr Voluson Expert 22 benötigt?

    Wir bieten Reparatur, Leihsonden und aufbereitete Sonden für alle GE Voluson Expert 22 kompatiblen Schallköpfe.