Zum Hauptinhalt springen
    Alle Systeme
    Ultraschallsystem

    LOGIQ E10s

    GE

    Premium-Ultraschallsystem mit cSound Imageformer (11,75 Mio. Kanäle), 23,8"-HDU-Display, 4 aktiven Sondenanschlüssen, B-Flow, RadiantFlow, Scherwellen-Elastographie, UGAP und erweitertem 3D/4D.

    24 kompatible Sonden

    Kompatible Sonden für GE LOGIQ E10s

    Standard

    Standard Sonden (21)

    GE 6S-D ultrasound transducer

    6S-D

    GE · Standard

    1.5–5 MHz

    6S-D — Phased array, 2–8 MHz, pediatric cardiac

    Reparatur
    GE BE9CS-D ultrasound transducer

    BE9CS-D

    GE · Standard

    4–11 MHz

    BE9CS-D — Endocavity biplane, 3–12 MHz, urology

    Reparatur
    GE C1-6-D ultrasound transducer

    C1-6-D

    GE · Standard

    1–6 MHz

    C1-6-D — XDclear convex, 1–6 MHz, 192 el

    Reparatur
    GE C1-6VN-D ultrasound transducer

    C1-6VN-D

    GE · Standard

    1–6 MHz

    C1-6VN-D — VNav XDclear convex, 1–6 MHz

    Reparatur
    GE C2-7-D ultrasound transducer

    C2-7-D

    GE · Standard

    2–7 MHz

    C2-7-D — Micro-convex, 1–6 MHz, 144 el

    Reparatur
    GE C2-7VN-D ultrasound transducer

    C2-7VN-D

    GE · Standard

    2–7 MHz

    C2-7VN-D — VNav micro-convex, 1–6 MHz

    Reparatur
    GE C2-9-D ultrasound transducer

    C2-9-D

    GE · Standard

    2–9 MHz

    C2-9-D — XDclear convex, 2–9 MHz, 192 el

    Reparatur
    GE C2-9VN-D ultrasound transducer

    C2-9VN-D

    GE · Standard

    2–9 MHz

    C2-9VN-D — VNav XDclear convex, 2–9 MHz

    Reparatur
    GE C3-10-D ultrasound transducer

    C3-10-D

    GE · Standard

    3–10 MHz

    C3-10-D — XDclear micro-convex, 2–11 MHz, 192 el

    Reparatur
    GE IC5-9-D ultrasound transducer

    IC5-9-D

    GE · Standard

    4–9 MHz

    IC5-9-D — Endocavity, 3–10 MHz, 192 el, 180° FOV

    Reparatur
    GE L2-9-D ultrasound transducer

    L2-9-D

    GE · Standard

    2–9 MHz

    L2-9-D — XDclear linear, 2–10 MHz, 192 el

    Reparatur
    GE L2-9VN-D ultrasound transducer

    L2-9VN-D

    GE · Standard

    2–9 MHz

    L2-9VN-D — VNav XDclear linear, 2–10 MHz

    Reparatur
    GE L3-12-D ultrasound transducer

    L3-12-D

    GE · Standard

    3–12 MHz

    L3-12-D — Linear, 3–12 MHz, 256 el

    Reparatur
    GE L6-24-D ultrasound transducer

    L6-24-D

    GE · Standard

    6–24 MHz

    L6-24-D — Linear, 6–20 MHz, 192 el, hockey stick

    Reparatur
    GE L8-18i-D ultrasound transducer

    L8-18i-D

    GE · Standard

    4–15 MHz

    L8-18i-D — Linear, 5–18 MHz, 168 el, intraoperative

    Reparatur
    GE M5Sc-D ultrasound transducer

    M5Sc-D

    GE · Standard

    1.5–4.6 MHz

    M5Sc-D — XDclear phased array, 1–5 MHz, 288 el, cardiac

    Reparatur
    GE ML4-20-D ultrasound transducer

    ML4-20-D

    GE · Standard

    4–20 MHz

    ML4-20-D — Matrix linear, 4–20 MHz, 1008 el

    Reparatur
    GE ML4-20VN-D ultrasound transducer

    ML4-20VN-D

    GE · Standard

    3–16 MHz

    ML4-20VN-D — VNav matrix linear, 3–16 MHz, 1008 el

    Reparatur
    GE ML6-15-D ultrasound transducer

    ML6-15-D

    GE · Standard

    4–15 MHz

    ML6-15-D — Matrix linear, 4–16 MHz, 1008 el

    Reparatur
    GE P2D ultrasound transducer

    P2D

    GE · Standard

    2–2 MHz

    P2D — CW pencil, 2.1 MHz, cardiac

    Reparatur
    GE P6D ultrasound transducer

    P6D

    GE · Standard

    6.3–6.3 MHz

    P6D — CW pencil, 6.3 MHz, cardiac

    Reparatur
    TEE

    TEE Sonden (1)

    GE 6Tc-RS ultrasound transducer

    6Tc-RS

    GE · TEE

    3–8 MHz

    6Tc-RS — TEE, 2–8 MHz, adult cardiac

    Reparatur
    3D/4D

    3D/4D Sonden (2)

    GE RAB6-D ultrasound transducer

    RAB6-D

    GE · 3D/4D

    2–8 MHz

    RAB6-D — 4D volume convex, 2–8 MHz, 192 el, OB/GYN

    Reparatur
    GE RIC5-9-D ultrasound transducer

    RIC5-9-D

    GE · 3D/4D

    4–9 MHz

    RIC5-9-D — 4D volume endocavity, 3–10 MHz, 192 el

    Reparatur

    Die auf dieser Website bereitgestellten Inhalte dienen ausschließlich allgemeinen Informationszwecken und werden ohne Gewähr auf Richtigkeit, Vollständigkeit oder Aktualität bereitgestellt. Bitte beachten Sie, dass Funktionen und Verfügbarkeit je nach Systemumgebung und Sondentyp variieren können und möglicherweise nicht in allen Konfigurationen vollständig verfügbar sind.

    Service für Ihr LOGIQ E10s benötigt?

    Wir bieten Reparatur, Leihsonden und aufbereitete Sonden für alle GE LOGIQ E10s kompatiblen Schallköpfe.